Practical temperature guides, thermometer comparisons and buying advice.
Infrared Thermometers

Fluke 572-2 Review: High-Temperature Infrared Thermometer Specs and Buying Guide

Fluke 572-2 high-temperature infrared thermometer: 900°C range, 60:1 distance-to-spot, K-type thermocouple input, emissivity and who it suits, from Fluke's own specifications.

As an Amazon Associate I earn from qualifying purchases. Product links in this article may earn us a commission at no extra cost to you. Read our affiliate disclosure

Gloved hand holding an infrared thermometer
Photo via Pexels

Editor’s note: This guide replaces our earlier Fluke 572-2 review, which is no longer available. It was rewritten in November 2026 from Fluke’s own product page and specifications (linked at the end). We haven’t tested the 572-2 ourselves, so this is a specifications and buying guide rather than a hands-on review. When we checked, Fluke’s online store listed it as out of stock.

Quick answer

  • What it is: a professional high-temperature infrared thermometer for industrial work. It measures from −22°F to 1652°F (−30°C to 900°C).
  • Long-distance targeting: a 60:1 distance-to-spot ratio with dual laser sighting, so you can measure small or distant targets.
  • Also a contact thermometer: a K-type thermocouple input (−454°F to 2501°F) shows probe and infrared temperatures together. A bead probe is included.
  • Pro features: adjustable emissivity (0.10–1.00) with a built-in materials table, high/low alarms, MIN/MAX/AVG/DIF, 99-point data storage and USB.
  • Who it’s for: furnaces, kilns, metals, glass, cement, power utilities and petrochemical work. For cooking or home use, it’s far more than you need.

The Fluke 572-2 sits at the top of Fluke’s handheld infrared thermometer range. Fluke positions it for high-temperature industrial environments such as power utilities, metal refining and smelting, glass, cement and petrochemicals. Its combination of a 1652°F maximum, a narrow 60:1 measurement spot and a built-in thermocouple input sets it apart from general-purpose IR guns. Here’s what the specifications mean in practice.

Fluke 572-2 specifications

Specification Fluke 572-2
Infrared range −30°C to 900°C (−22°F to 1652°F)
IR accuracy (at 23°C ambient) ≥ 0°C: ±1°C or ±1% of reading, whichever is greater (≥ 32°F: ±2°F or ±1%). Less accurate below freezing: ±2°C from −10°C to 0°C, ±3°C below −10°C
IR repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Distance-to-spot ratio 60:1 (at 90% energy); minimum spot size 19 mm
Laser sighting Offset dual laser, output < 1 mW (FDA Laser Class II)
Spectral response 8–14 μm
Response time < 500 ms (95%)
Emissivity Adjustable 0.10 to 1.00 in 0.01 steps, or from a built-in table of common materials
Thermocouple input K-type, −270°C to 1372°C (−454°F to 2501°F); ±1% or 1°C, whichever is greater, at −40°C and above
Included probe K-type bead probe, −40°C to 260°C (−40°F to 500°F), ±1.1°C (±2.0°F) from 0°C to 260°C; 1 m cable
Display resolution 0.1°C / 0.1°F
Display Dot matrix, 98 × 96 pixels, with menus; two-level backlight
Functions MIN/MAX/AVG/DIF, audible and two-color visual hi/low alarms, trigger lock, 20-second last-reading hold
Data Stores 99 data sets; USB 2.0 interface
Power 2 × AA; 8 hours with laser and backlight on, 100 hours with them off (continuous use)
Operating temperature 0°C to 50°C (32°F to 122°F)
Weight 0.322 kg (0.71 lb)
In the box K-type bead probe, hard case, USB cable

All figures are from Fluke’s product page.

What the key specs mean

900°C range for hot processes

Many general-purpose infrared thermometers stop well short of that. The 572-2’s 1652°F (900°C) maximum covers furnace shells, kiln walls, molten-metal handling equipment, steam lines and other high-temperature surfaces that cheaper tools can’t read. Accuracy is best at and above freezing (±1% or ±1°C), which is where industrial users will spend most of their time.

60:1 distance-to-spot ratio

Every IR thermometer averages the temperature over a circular spot that grows with distance. At 60:1, the spot is about 1 inch across at 60 inches away. That lets you measure small targets, such as a single pipe or a terminal, from a safe distance without picking up surrounding surfaces. Fluke’s dual laser sighting helps you target the spot quickly. Learn more in our infrared vs probe thermometer guide.

Adjustable emissivity

Infrared readings depend on how well a surface emits heat. Shiny metals emit poorly and read low unless you correct for them. The 572-2 lets you set emissivity from 0.10 to 1.00 or choose a material from its built-in table, which matters for the oxidized and polished metals common in industrial settings.

Built-in thermocouple input

The K-type input accepts standard mini-connector thermocouples, including ones you already own or have installed. With the included bead probe, you can check an infrared reading against a contact reading, or take temperatures where IR isn’t suitable, such as air or shiny surfaces. The display shows both readings at once.

Pros

  • Measures up to 1652°F (900°C)
  • Very narrow 60:1 spot with dual lasers
  • K-type thermocouple input, probe included
  • Adjustable emissivity with a materials table
  • Alarms, data logging and USB
  • Runs on standard AA batteries

Cons

  • Professional pricing, well above general-purpose IR thermometers
  • Lower accuracy below freezing
  • Short battery life with laser and backlight on (8 hours continuous)
  • Calibration certificate is not included (available to order from Fluke)

Check Price on Amazon

Who should buy the Fluke 572-2?

A good fit if…

  • You measure very hot surfaces, such as furnaces, kilns, boilers, metals or glass, beyond the range of general-purpose IR thermometers.
  • You need to read small or distant targets accurately.
  • You want IR and thermocouple readings in one tool, with logging for reports.

Look at something else if…

Using an industrial IR thermometer safely

  • Don’t look into the laser or point it at people or reflective surfaces. The 572-2 uses a Class II laser.
  • Set the correct emissivity for the material, or verify with a contact probe.
  • Keep the instrument within its operating range of 32°F to 122°F (0°C to 50°C) when working near hot equipment.
  • Follow your site’s PPE and safety rules around high-temperature processes.

Bottom line

The Fluke 572-2 is a specialist tool for high-temperature industrial measurement. Its 900°C range, 60:1 optics, adjustable emissivity and built-in thermocouple input make it well suited to furnaces, metals, glass and power applications. For everyday or kitchen use, a far simpler infrared thermometer is the better buy.

FAQ

What is the temperature range of the Fluke 572-2?

Infrared: −22°F to 1652°F (−30°C to 900°C). Through its K-type thermocouple input: −454°F to 2501°F (−270°C to 1372°C), depending on the probe used.

What is the distance-to-spot ratio?

60:1, according to Fluke, with a minimum spot size of 19 mm.

Does the Fluke 572-2 come with a probe?

Yes. It includes a K-type thermocouple bead probe, plus a hard case and USB cable.

Does it come with a calibration certificate?

No. Fluke says a certificate of calibration isn’t included but can be ordered through Fluke Service.

What batteries does it use?

Two standard AA batteries. Fluke lists 8 hours of continuous use with the laser and backlight on, or 100 hours with both off.

Sources: Fluke 572-2 High Temperature Infrared Thermometer product page and specifications (including Fluke’s answer on calibration certificates). Checked November 2026.