Practical temperature guides, thermometer comparisons and buying advice.
Comparisons

Etekcity Lasergrip 1025D vs 1030D: Dual-Laser Infrared Thermometers Compared

Etekcity Lasergrip 1025D vs 1030D compared: adjustable vs fixed emissivity, voltage detection, color backlight alerts and the specs they share.

As an Amazon Associate I earn from qualifying purchases. Product links in this article may earn us a commission at no extra cost to you. Read our affiliate disclosure

Industrial dial temperature gauge
Photo via Pexels

Editor’s note: Originally published December 2020. Reviewed and updated November 2026. Some models mentioned here may have been updated or discontinued since; check current availability and specifications before buying.

The Etekcity Lasergrip 1025D and 1030D are budget-friendly infrared thermometers that share dual lasers, a 12:1 distance-to-spot ratio and the same -58°F to 1022°F range. The main difference is emissivity: the 1025D lets you adjust it from 0.1 to 1.0, while the 1030D is fixed at 0.95. The 1025D also adds non-contact voltage detection, and the 1030D adds a color-coded backlight.

The manufacturer lists accuracy within ±2% for both. As with most thermometers in this price range, expect them to be less accurate than more expensive models.

1025D vs 1030D at a glance

Feature Lasergrip 1025D Lasergrip 1030D
Lasers Dual Dual
Distance-to-spot ratio 12:1 12:1
Temperature range -58°F to 1022°F (-50°C to 550°C) -58°F to 1022°F
Listed accuracy ±2% ±2%
Emissivity Adjustable, 0.1–1.0 Fixed at 0.95
Non-contact voltage detection Yes, 90–600 V No
Color backlight hot/cold indicator No Yes
Power One 9 V battery One 9 V battery

Why emissivity matters

Emissivity describes how well a surface gives off infrared energy, and it varies with the material and texture you’re measuring. A fixed 0.95 setting is convenient and predictable for many common surfaces, while adjustable emissivity lets you compensate for different surfaces. For most buyers who measure a variety of things, adjustable emissivity is the more versatile choice. For more on how IR readings work, see infrared vs probe thermometers.

The two thermometers

Etekcity Lasergrip 1025D

The 1025D uses dual lasers to show the area you’re measuring, and its 12:1 distance-to-spot ratio lets you measure from farther away than many thermometers in its class. It works indoors and outdoors and holds the reading automatically after you measure.

It can also switch to non-contact voltage mode to detect live current from 90 to 600 volts, useful as a quick check on outlets or exposed wires. Adjustable emissivity lets you compensate for different surface textures.

Listed specifications

  • Dual lasers
  • Distance-to-spot ratio: 12:1
  • Range: -58°F to 1022°F (-50°C to 550°C)
  • Accuracy: ±2%
  • Emissivity: adjustable, 0.1–1.0
  • Non-contact voltage detection: 90–600 V
  • Automatic data hold
  • Power: one 9 V battery

Pros

  • Many features for a budget price
  • Dual lasers and 12:1 ratio
  • Adjustable emissivity

Cons

  • Voltage detection was reported to work poorly
  • May be less accurate than more expensive thermometers
  • Not weather or drop resistant

Check Price on Amazon

Etekcity Lasergrip 1030D

The 1030D shares the 12:1 ratio, dual lasers and -58°F to 1022°F range. Its standout feature is a temperature reference function: you set a reference temperature, and the backlight turns blue or red to show whether the scanned item is colder or hotter, in 1°F increments.

It switches between Fahrenheit and Celsius, holds data automatically, and has auto-off and a low-battery indicator. The body has an ABS coating intended to reduce scratches and everyday wear.

Listed specifications

  • Dual lasers
  • Distance-to-spot ratio: 12:1
  • Range: -58°F to 1022°F
  • Accuracy: ±2%
  • Emissivity: fixed at 0.95
  • Blue/red backlight for colder/hotter than reference
  • °F/°C switching, automatic data hold
  • Auto-off and low-battery indicator
  • Power: one 9 V battery

Pros

  • Budget price for a dual-laser 12:1 thermometer
  • Color backlight shows hotter/colder at a glance
  • Auto-off and low-battery indicator

Cons

  • Emissivity is fixed at 0.95
  • Not as accurate as more expensive IR thermometers
  • Not weather or drop resistant

Check Price on Amazon

Which should you choose?

  • Choose the 1025D if you measure different materials and want adjustable emissivity, or you’d like a basic voltage check built in.
  • Choose the 1030D if you mostly measure common surfaces where 0.95 emissivity works, and you’d find hot/cold color alerts useful.

Want to compare more models? See our reviews of the Lasergrip 800 and Lasergrip 1080, or our budget infrared thermometer guide.

Bottom line

These two thermometers are nearly identical on range, ratio and accuracy. Pick the 1025D for adjustable emissivity and voltage detection, or the 1030D for its color-coded reference alerts.

FAQ

What is the main difference between the Etekcity 1025D and 1030D?

Emissivity. The 1025D is adjustable from 0.1 to 1.0, while the 1030D is fixed at 0.95.

What battery do they use?

Both use one 9 V battery. If yours acts up after a battery change, see how to reset an infrared thermometer.

Can the 1025D detect voltage?

Yes. It has a non-contact voltage mode for detecting live current from 90 to 600 volts.